Our testing laboratory is equipped with modern testing equipment that meets Russian and global requirements and carries out mechanical and climatic tests, multiple and single impacts, linear acceleration, exposure to solar radiation, high humidity, as well as static and dynamic dust tests, atmospheric pressure, electric insulation strength in accordance with the field of certification.
List of types of tests conducted in the control and testing laboratory of JSC "PA “UOMP"
Types of tests for external factors effect | Designation of RD establishing test standards | The ranges of characteristics of the external factors reproduced by the measuring equipment | Mass-dimensional characteristics of the tested products, kg, mm х mm х mm | |
1 High ambient temperature test | For periodic tests, the technical conditions for the products tested. | Temperature effect from 0ºC to + 150ºС | 500 | 2,850х600х400 |
2 Low ambient temperature test | Temperature effect from 0ºC to -70ºС | 500 | –//– | |
3 Exposure to high humidity | Relative humidity from 10% to 98% | 500 | –//– | |
4 Temperature change test | Temperature effect from -70ºС to +150ºС | 500 | –//– | |
5 High pressure air (gas) test | Increased pressure up to 3 atm | 2 | 130х130х450 | |
6 Rapid change in pressure (take-off) test | Low pressure up to 30 mm Hg | 200 | 850х600х400 | |
7 Sand and dust tests | Air speed 1.0 m/s | 200 | 500х300х300 | |
8 Leak tests | Minimum flow of helium not more than 7х10-12 m х cPs | 2 | 300х200х100 | |
9 Tests for the effects of atmospheric precipitation (rain) | Rain intensity 5 mm | 500 | 2,850х400х400 | |
10 Vibration tests | Vibration effect in the frequency range from 5 Hz to 2000 Hz with acceleration from 3m / s2 | 500 | 2,850х600х600 | |
11 Impact tests | Maximum acceleration 1,000gDuration from 2 ms to 35 ms. Duration from 2 ms to 35 ms. (half-sine) 10 ms to 70 ms trapezoidal | 500 | 2,850х600х600 | |
12 Linear acceleration resistance tests | Linear overloads from 10 m/s2 to 500 m/s2 | 200 | 850х600х400 | |
13 Dielectric strength of insulation | Operating voltage range up to 10 kW AC and DC | 30 | 600х400х300 | |
14 Test for solar radiation influence | High temperature from +20ºС to +55ºС; integrated density of light flux radiation 1200 W/m2; density of UV-radiation 54 W/m2. | 100 | 800х500х500 | |
15 Test for dew and internal icing influence | Temperature influence from -75ºС to +160 ºС; Low pressure from 760 mm.Hg to 0,75 mm Hg Relative humidity from 20% to 98 % within the temperature range from +30 °C to +60 °C. | 500 | 1800х3800х1800 | |
16 Test for influence of atmospheric low pressure at aero-transportation | Temperature influence from -75ºС to +160 ºС; Low pressure from 760 mm Hg to 0,75 mm Hg | 500 | 1800х3800х1800 | |
17 Test for influence of atmospheric condensed precipitations (hoarfrost and dew) | Temperature influence from -75ºС to +180ºС | 500 | 1800х3800х1800 |